  • #4935
    admin
    Keymaster

      RTO (Regenerative Thermal Oxidizer) is an organic waste gas treatment
      technology that has emerged in China in the past decade. This technology is
      particularly suitable for the treatment of organic waste gases with low to
      medium air volume, high to medium concentration, and complex composition. Due to
      its high treatment efficiency, minimal secondary pollution, and stable
      operation, it has been highly sought after by environmental protection
      departments in many places. After years of use, RTO has also exposed some
      problems, among which the most prominent ones are safety issues such as fire and
      explosion of RTO.

      According to the survey on the usage of some enterprises, there are mainly
      the following reasons:

      (1) Some enterprises did not consider the use of RTO in the design of their
      main equipment, resulting in inadequate safety measures, insufficient
      automation, and mismatch between actual operating conditions and equipment
      loads.

      (2) The composition of organic waste gas from enterprises is relatively
      diverse and the gas volume is unstable. The characteristics of intermittent
      production in fine chemical and other enterprises result in intermittent changes
      in the concentration and volume of organic waste gas.

      (3) Some companies have not adequately selected equipment and facilities
      based on their own actual situation. The actual operating conditions after
      production differ significantly from the ideal conditions of RTO.

      (4) Inadequate consideration of sudden issues, inadequate and untimely
      response to unexpected problems.

      In order to prevent RTO safety accidents and reduce accident losses,
      environmental design units must consider safety issues as the first priority
      when designing RTOs. Currently, common measures can be summarized as
      follows:

      (1) Designers need to understand the customer's process, clarify the emission
      characteristics of organic waste gas during the process, and identify possible
      unexpected factors.

      (2) Strictly controlling the concentration of organic compounds imported into
      RTO to a safe level is the most fundamental measure to prevent explosions. RTO
      itself is an ignition source, and if the inlet concentration exceeds the lower
      explosive limit, even if explosion-proof fans and anti-static pipes are used
      earlier, it will be of no use. Due to the significant decrease in the lower
      explosive limit of organic compounds with the increase of gas temperature, and
      the sudden emission of organic waste gas from chemical enterprises, the inlet
      concentration must be much lower than the lower explosive limit. The main
      measures:

      ① Include installing concentration monitoring instruments at the exhaust
      gas inlet and necessary exhaust gas branch inlet; 

      ② For high concentration
      exhaust gas, add a dilution air valve at the RTO inlet; 

      ③ Add a buffer tank to
      the exhaust inlet, and the volume of the buffer tank should be designed
      appropriately; 

      ④ The interlocking control between concentration monitoring
      instruments, dilution air valves, RTO fans and other equipment enables the
      correct action to be taken immediately in case of sudden problems.

      (3) In order to reduce the losses caused by safety accidents, the following
      measures are generally taken: 

      ① Add a flame arrester at the RTO inlet to prevent
      backfire; 

      ② Add explosion-proof discs at the corners of the combustion chamber,
      buffer tank, and pipeline; 

      ③ Set up some fire-fighting facilities near the
      equipment.